TW RANGE
Single-stage accessible thermostatic chambers – temperature range –40°C + 120°C
- • Light alloy frame, painted in RAL 9010;
- • Completely removable aluminium finishing panels, painted in RAL 9010;
- • Fire-proof (MUPAM) glass wool thermal insulation
- • Internal cell made of 18/8 AISI 304 stainless steel with 15/10 thickness;
- • Forced air circulation obtained by 1 or more fans with blades with external extended axis motor;
- PID electronic regulator with temperature digital display and with RS 422 serial interface, which can be monitored from a compatible PC;
- High and low temperature fail-safe electronic thermostat;
- High temperature fail-safe mechanical thermostat, connected to an automatic thermostat with spring release coil;
- Door safety switch;
- Emergency button;
- Electric system with moulded modular components to make possible maintenance operations easier and quicker;
- All instruments are placed in the electric control board on the right or left side of the chamber.
PERFORMANCE
TEMPERATURE
- Range: - 40°C to + 120 °C;
- Precision: ± 0,5 °C after stabilisation;
- Heat-up and cool-down rate: average of 2 °C/min in temperature range of – 40° to 120°C
TW RANGE
Two-stage accessible thermostatic chambers – temperature range -70°C + 120°C
PERFORMANCE
TEMPERATURE
- Range: -70°C to + 120 °C;
- Precision: ± 0,5 °C after stabilisation;
- Heat-up and cool-down rate: average of 2 °C/min in temperature range of – 70° to 120°C
- OPTION: linear heat-up and cool-down rate 5, 7, 10°C/min up to –54°C
THW SERIES
Single and two-stage accessible thermostatic chambers – temperature range –40°C / - 70°C + 120°C
-
PID electronic regulator with relative humidity digital display and with RS 422 serial interface – which can be monitored from a compatible PC;
-
Electronic capacitive probe to determine relative humidity as a percentage;
HUMIDIFICATION SYSTEM
- The humidification system is operated by a CAREL steam generator, which is directly monitored by the control device;
DEHUMIDIFICATION SYSTEM
- Dehumidification will take place through the condensation of humidity on a specific large refrigerated battery, in order to assure dehumidification gradient volumes. The chamber is built so that the condensate is automatically drained off the chamber.
PERFORMANCE
TEMPERATURE
- Range: - 40°C/-70 to + 120°C;
- Precision: ± 0.5 °C after stabilisation;
- Heat-up and cool-down rate: average of 2 °C/min in temperature range of – 40°/-70°C to + 120°C
RELATIVE HUMIDITY
- Range: from 10% to 98% of climatic range from 10°C to 95°C with dew-point limitation;
- Precision: ± 0.5% to ± 2%;

Serie THW 6,5 m/c
|
Serie THW 16 m/c |
Serie THF fytologic chambers(grow up plant experiment)
|
|