PRODUCTS
HOT-HUMID
 Features

TH RANGE
Single-stage climatic chambers – temperature range –40°C + 200°C

  • Light alloy frame, painted in RAL 9010;
  • Completely removable aluminium finishing panels, painted in RAL 9010;
  • Fire-proof glass wool (MUPAM) thermal insulation;
  • Internal cell made of 18/8 AISI 304 stainless steel with 15/10 thickness;
  • Forced air circulation obtained by 1 or more fans with blades with external extended axis motor;
  • PID electronic regulator with digital temperature display and with RS 422 serial interface, which can be piloted from a compatible PC;
  • PID electronic regulator with digital relative humidity display and with RS 422 serial interface, which can be piloted from a compatible PC
  • Electronic capacitive probe to determine relative humidity as a percentage;
  • High and low temperature fail-safe electronic thermostat;
  • High temperature fail-safe mechanical thermostat, connected to an automatic thermostat with spring release coil;
  • Door safety switch;
  • Emergency button;
  • Electric system with moulded modular components to make possible maintenance operations easier and quicker;
  • All instruments are placed in a drawer on the front of the chamber;

PERFORMANCE

TEMPERATURE

  • Range: - 40°C to + 200 °C;
  • Precision: ±  0,5 °C after stabilisation;
  • Heat-up and cool-down rate: average of 2 °C/min in temperature range of – 40° to 200°C


TH RANGE

Two-stage climatic chambers – temperature range -80°C + 200°C

PERFORMANCE

TEMPERATURE

  • Range: - 80°C to + 200 °C;
  • Precision: ±  0,5 °C after stabilisation;
  • Heat-up and cool-down rate: average of 2 °C/min in temperature range of – 80° to 200°C
  • OPTION: linear heat-up and cool-down rate 5, 7, 10°C/min up to –54°C

RELATIVE HUMIDITY

  • Range: 10%  to 98% of climatic range of +10°C to 95 °C with dew-point limitation ;
  • Precision: ± 0,5%   ± 2%;

HUMIDIFACTION SYSTEM

  • The humidification system is operated by a steam generator, which is directly monitored by the control device;
  • Polyethylene tank for supplying the steam generator with distilled water, so as to avoid limescale deposits on the components tested;

DEHUMIDIFICATION SYSTEM

  • Dehumdification will take place through the condensation of humidity on a specific large refrigerated battery, in order to assure dehumidification gradient volumes.
    The chamber is built so that the condensate is automatically drained off the chamber.


Serie TH 
for tests on load cells

Serie TH

Serie TH
with LCD PC and touch screen